<?xml-stylesheet href='/static/xsl/oai.xsl' type='text/xsl'?>
<ri:Resource created="2007-07-09T20:36:20Z" status="active" updated="2025-05-19T09:50:00Z" version="1.2" xmlns:ri="http://www.ivoa.net/xml/RegistryInterface/v1.0" xmlns:vr="http://www.ivoa.net/xml/VOResource/v1.0" xmlns:vs="http://www.ivoa.net/xml/VODataService/v1.1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ivoa.net/xml/VOResource/v1.0 http://vo.ari.uni-heidelberg.de/docs/schemata/VOResource.xsd http://www.ivoa.net/xml/VODataService/v1.1 http://vo.ari.uni-heidelberg.de/docs/schemata/VODataService.xsd" xsi:type="vs:CatalogService"><title>A recalibration of optical photometry</title><shortName>J/AJ/131/1184</shortName><identifier>ivo://CDS.VizieR/J/AJ/131/1184</identifier><altIdentifier>doi:10.26093/cds/vizier.51311184</altIdentifier><curation><publisher ivo-id="ivo://CDS">CDS</publisher><creator><name>Maiz-Apellaniz J.</name></creator><date role="Updated">2017-06-27T06:38:52Z</date><date role="Created">2007-07-09T20:36:20Z</date><contact><name>CDS support team</name><address>CDS, Observatoire de Strasbourg, 11 rue de l'Universite, F-67000 Strasbourg, France</address><email>cds-question@unistra.fr</email></contact></curation><content><subject>photometry</subject><subject>visible-astronomy</subject><subject>broad-band-photometry</subject><subject>medium-band-photometry</subject><description>I use high-quality Hubble Space Telescope (HST) spectrophotometry to analyze the calibration of three popular optical photometry systems: Tycho-2 B_T_ and V_T_, Stromgren uvby, and Johnson UBV.</description><source format="bibcode">2006AJ....131.1184M</source><referenceURL>https://cdsarc.cds.unistra.fr/viz-bin/cat/J/AJ/131/1184</referenceURL><type>Catalog</type><contentLevel>Research</contentLevel><relationship><relationshipType>IsServedBy</relationshipType><relatedResource ivo-id="ivo://CDS.VizieR/TAP">TAP VizieR generic service</relatedResource></relationship></content><rights>https://cds.unistra.fr/vizier-org/licences_vizier.html</rights><capability><interface xsi:type="vr:WebBrowser"><accessURL use="full">https://vizier.cds.unistra.fr/viz-bin/VizieR-2?-source=J/AJ/131/1184</accessURL><mirrorURL title="VizieR at IUCAA: Pune, India">https://vizier.iucaa.in/viz-bin/VizieR-2?-source=J/AJ/131/1184</mirrorURL><mirrorURL title="VizieR at SAAO: SAAO, South Africa">http://vizieridia.saao.ac.za/viz-bin/VizieR-2?-source=J/AJ/131/1184</mirrorURL></interface></capability><capability><interface xsi:type="vs:ParamHTTP"><accessURL use="base">https://vizier.cds.unistra.fr/viz-bin/votable?-source=J/AJ/131/1184</accessURL><mirrorURL title="VizieR at IUCAA: Pune, India">https://vizier.iucaa.in/viz-bin/votable?-source=J/AJ/131/1184</mirrorURL><mirrorURL title="VizieR at SAAO: SAAO, South Africa">http://vizieridia.saao.ac.za/viz-bin/votable?-source=J/AJ/131/1184</mirrorURL><queryType>GET</queryType><resultType>text/xml+votable</resultType></interface></capability><capability standardID="ivo://ivoa.net/std/TAP#aux"><interface xsi:type="vs:ParamHTTP" role="std"><accessURL use="base">https://tapvizier.cds.unistra.fr/TAPVizieR/tap</accessURL></interface></capability><coverage><footprint ivo-id="ivo://ivoa.net/std/moc"/><waveband>Optical</waveband></coverage><tableset><schema><name>default</name><table><name>J/AJ/131/1184/table1</name><description>Recommended photon-counting sensitivity curves for the Tycho B_T_V_T_ system</description><column><name>recno</name><description>Record number assigned by the VizieR team. Should Not be used for identification.</description><ucd>meta.record</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>BTlambda</name><description>? Tycho B_T_ filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType><flag>nullable</flag></column><column><name>BTph</name><description>? Tycho B_T_ filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType><flag>nullable</flag></column><column><name>VTlambda</name><description>Tycho V_T_ filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>VTph</name><description>Tycho V_T_ filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType></column></table><table><name>J/AJ/131/1184/table2</name><description>Recommended photon-counting sensitivity curves for the Stromgren uvby standard system</description><column><name>recno</name><description>Record number assigned by the VizieR team. Should Not be used for identification.</description><ucd>meta.record</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>ulambda</name><description>? Stromgren u filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType><flag>nullable</flag></column><column><name>uph</name><description>? Stromgren u filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType><flag>nullable</flag></column><column><name>vlambda</name><description>Stromgren v filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>vph</name><description>Stromgren v filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType></column><column><name>blambda</name><description>Stromgren b filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>bph</name><description>Stromgren b filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType></column><column><name>ylambda</name><description>Stromgren y filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>yph</name><description>Stromgren y filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType></column></table><table><name>J/AJ/131/1184/table3</name><description>Recommended photon-counting sensitivity curves for the Johnson UBV standard system</description><column><name>recno</name><description>Record number assigned by the VizieR team. Should Not be used for identification.</description><ucd>meta.record</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>Ulambda</name><description>? Johnson U filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType><flag>nullable</flag></column><column><name>Uph</name><description>? Johnson U filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType><flag>nullable</flag></column><column><name>Blambda</name><description>? Johnson B filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType><flag>nullable</flag></column><column><name>Bph</name><description>? Johnson B filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType><flag>nullable</flag></column><column><name>Vlambda</name><description>Johnson V filter wavelength in Angstroms</description><unit>0.1nm</unit><ucd>instr.filter;em.wl.central</ucd><dataType xsi:type="vs:VOTableType">int</dataType></column><column><name>Vph</name><description>Johnson V filter sensitivity</description><ucd>instr.sensitivity</ucd><dataType xsi:type="vs:VOTableType">float</dataType></column></table></schema></tableset></ri:Resource>